CVE-2026-58115: Node-RED HTTP editor / admin interface (no authentication enforced)
Siemens SIMATIC IoT2050 devices running Industrial OS with Node-RED do not enforce authentication on the Node-RED HTTP interface, so an unauthenticated remote attacker can create flows that execute code with maximum privileges. VulnCheck observed in-the-wild exploitation from October 30, 2026, with 16 attacks by November 1 dropping a Linux bot and persistent webshells.
Executive Summary & Technical Impact
Siemens SIMATIC IoT2050 devices running Industrial OS with Node-RED do not enforce authentication on the Node-RED HTTP interface, so an unauthenticated remote attacker can create flows that execute code with maximum privileges. VulnCheck observed in-the-wild exploitation from October 30, 2026, with 16 attacks by November 1 dropping a Linux bot and persistent webshells.
Tracked under CVE-2026-58115 (CWE-306 (Missing Authentication for Critical Function)), this vulnerability affects SIMATIC IoT2050 Advanced, Basic, M.2 and SM, all versions < V4.3.4-1 running Industrial OS with Node-RED installed; any Node-RED instance reachable without adminAuth is exposed to the same attack pattern and carries a severity score of 10.0 (CVSS 3.1 and 4.0, Siemens) (CRITICAL). Engineering and security operations teams running SIMATIC IoT2050 (Industrial OS with Node-RED) should prioritize upgrading to SIMATIC IoT2050 V4.3.4-1 or later; for standalone Node-RED, enable adminAuth and restrict network access.
Remediation & Patch Guidance
- Update SIMATIC IoT2050 devices to V4.3.4-1 or later.
- Uninstall Node-RED where it is not needed.
- Enable adminAuth in Node-RED settings.js and keep the editor port (1880 by default) off the internet.
- Review deployed flows for unexpected exec nodes or HTTP-in endpoints that could be webshells.
Frequently Asked Questions (CVE-2026-58115)
What versions are affected by CVE-2026-58115?
CVE-2026-58115 affects SIMATIC IoT2050 Advanced, Basic, M.2 and SM, all versions < V4.3.4-1 running Industrial OS with Node-RED installed; any Node-RED instance reachable without adminAuth is exposed to the same attack pattern in SIMATIC IoT2050 (Industrial OS with Node-RED) (Node-RED HTTP editor / admin interface (no authentication enforced)).
How do I patch or remediate CVE-2026-58115?
Upgrade affected deployments to SIMATIC IoT2050 V4.3.4-1 or later; for standalone Node-RED, enable adminAuth and restrict network access and verify the remediation steps listed above.
What is the CVSS score of CVE-2026-58115?
CVE-2026-58115 is rated CRITICAL with a CVSS score of 10.0 (CVSS 3.1 and 4.0, Siemens) (vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H; one unauthenticated HTTP request deploys a flow with an exec node).
Two Old Doors Now Being Kicked In: Node-RED CVE-2026-58115 and WordPress CVE-2026-119977 Are Exploited
A CVSS 10 missing-auth bug in Node-RED on Siemens IoT2050 gateways is under automated attack, and CISA gave federal agencies until November 6 to patch a WordPress upgrade-window RCE.
Read full engineering post-mortem (5 min read) →